{"product_id":"20amp-32dc-circuit-breaker-push-to-reset","title":"Carling Technologies 20A 32VDC Push to Reset Circuit Breaker","description":"\u003ch3\u003e\u003cb\u003eCarling Technologies 20A 32VDC Push-to-Reset Thermal Supplementary Circuit Breaker\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eCarling Technologies 20A 32VDC Push-to-Reset Circuit Breaker\u003c\/b\u003e (commonly designated under the \u003cb\u003eCLB-Series \/ CMB-Series\u003c\/b\u003e) is a compact, single-pole \u003cb\u003ethermal supplementary circuit protector\u003c\/b\u003e engineered for reliable overcurrent protection in low-voltage DC marine switchboards, automotive dashboards, generator panels, and battery distribution systems.\u003c\/p\u003e\n\u003cp\u003eDesigned as a manual-reset, push-to-reset unit, the breaker allows normal continuous current flow up to \u003cb\u003e\u003cspan class=\"math-inline\"\u003e20 A\u003c\/span\u003e\u003c\/b\u003e while automatically tripping during sustained electrical overloads or short circuits. Once an overcurrent event is cleared, pressing the visible red\/white actuator button instantly restores power to downstream branch circuits. Constructed with a durable thermoplastic housing and \u003cspan class=\"math-inline\"\u003e1\/4\"\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e6.35 mm\u003c\/span\u003e) quick-connect tab terminals, it mounts easily through standard \u003cspan class=\"math-inline\"\u003e3\/8\"\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e10 mm\u003c\/span\u003e) panel cutouts.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Panel-Mount Design:\u003c\/b\u003e Snaps or threads into a standard \u003cspan class=\"math-inline\"\u003e3\/8\"\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e10 mm\u003c\/span\u003e) round panel hole, ideal for space-constrained marine consoles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIgnition Protected:\u003c\/b\u003e Meets ISO 8846 and SAE J1171 standards, allowing safe installation in gasoline and diesel engine compartments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eVisible Trip Status:\u003c\/b\u003e The central push button pops outward upon tripping to provide immediate visual confirmation of an open circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQuick-Connect Terminals:\u003c\/b\u003e \u003cspan class=\"math-inline\"\u003e0.250\"\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e6.35 mm\u003c\/span\u003e) male spade terminals enable rapid, secure field crimp connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCarling Technologies (Littelfuse)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCLB-Series \/ CMB-Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBreaker Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eThermal Supplementary Protector (Push-to-Reset)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNumber of Poles\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e1-Pole (Single Pole)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRated Current \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e20 A\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMaximum Operating Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e32 VDC \/ 250 VAC\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e50\/60 Hz\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterrupting Capacity \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e1000 A\u003c\/span\u003e @ \u003cspan class=\"math-inline\"\u003e32 VDC \/ 125 VAC\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eReset Mechanism\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManual Push-to-Reset (Non-replaceable thermal bimetal)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDielectric Strength\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e1500 VAC\u003c\/span\u003e (1 minute)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTerminal Style\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e0.250\"\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e6.35 mm\u003c\/span\u003e) Male Quick-Connect Spade Tabs\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePanel Cutout Diameter\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e∅ 3\/8\"\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e10.0 mm\u003c\/span\u003e thread with knurled\/hex nut)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eHousing Material\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBlack Thermoplastic (UL 94 V-0 Rated)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e-10°C\u003c\/span\u003e to \u003cspan class=\"math-inline\"\u003e+60°C\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e14°F\u003c\/span\u003e to \u003cspan class=\"math-inline\"\u003e140°F\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRegulatory Approvals\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eUL 1077, CSA C22.2, CE, ISO 8846, SAE J1171 (Ignition Protected)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"DC Components","offers":[{"title":"Default Title","offer_id":45850801635411,"sku":"20Amp_32DC_MCB","price":8.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1166\/3720\/files\/eeavli4l5wn1q1uwcvzdky4f.jpg?v=1793612230","url":"https:\/\/www.obmgonline.com\/products\/20amp-32dc-circuit-breaker-push-to-reset","provider":"OBMG Online","version":"1.0","type":"link"}