{"product_id":"acti-9-iid-rccb-2p-63a-30ma-type-ac","title":"Schneider A9R71263 Acti9 iID RCCB 2P 63A 30mA Type AC","description":"\u003ch3\u003e\u003cb\u003eSchneider Electric Acti9 iID 2-Pole 63A 30mA Type AC RCCB (A9R71263)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eSchneider Electric A9R71263\u003c\/b\u003e is a high-performance 2-pole (\u003cspan class=\"math-inline\"\u003e2P\u003c\/span\u003e) Residual Current Circuit Breaker (RCCB \/ RCD) from the premium Acti9 iID series. Rated for a nominal current of \u003cb\u003e\u003cspan class=\"math-inline\"\u003e63 A\u003c\/span\u003e\u003c\/b\u003e with an earth leakage trip sensitivity of \u003cb\u003e\u003cspan class=\"math-inline\"\u003e30 mA\u003c\/span\u003e\u003c\/b\u003e, it provides instantaneous personal protection against electric shock from direct\/indirect contact and reduces fire hazards caused by earth fault currents in single-phase (\u003cspan class=\"math-inline\"\u003e230 V AC\u003c\/span\u003e) electrical networks.\u003c\/p\u003e\n\u003cp\u003eDesigned as a \u003cb\u003eType AC\u003c\/b\u003e residual current device, it detects sinusoidal AC earth leakage currents. It features Schneider Electric’s signature \u003cb\u003eVisiSafe\u003c\/b\u003e green indicator window (guaranteeing physical contact separation during maintenance) and \u003cb\u003eVisiTrip\u003c\/b\u003e red indicator flag for fast localized fault troubleshooting.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eVisiSafe \u0026amp; VisiTrip Technology:\u003c\/b\u003e Integrated mechanical indicators provide unambiguous visual proof of open contacts for safe downstream maintenance and quick identification of tripped circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInstantaneous Trip Response:\u003c\/b\u003e Delivers rapid earth leakage tripping to protect against fatal electric shocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDouble Clip DIN Rail Mounting:\u003c\/b\u003e Allows easy removal and installation on standard \u003cspan class=\"math-inline\"\u003e35 mm\u003c\/span\u003e DIN rail without disassembling adjacent busbars.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHigh Electrical Endurance:\u003c\/b\u003e Capable of up to \u003cspan class=\"math-inline\"\u003e10,000\u003c\/span\u003e electrical operating cycles and \u003cspan class=\"math-inline\"\u003e20,000\u003c\/span\u003e mechanical operating cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActi9\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProduct Name\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eActi9 iID\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProduct Code \/ SKU\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eA9R71263\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePoles Description\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e2P (\u003cspan class=\"math-inline\"\u003e1P + N\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNeutral Position\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLeft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRated Current \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e63 A\u003c\/span\u003e\u003c\/b\u003e at \u003cspan class=\"math-inline\"\u003e40°C\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEarth-Leakage Sensitivity \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e30 mA\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEarth-Leakage Protection Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eType AC\u003c\/b\u003e (Sinusoidal AC Leakage Detection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEarth-Leakage Protection Timing\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRated Operational Voltage \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e\u003cspan class=\"math-inline\"\u003e220 to 240 V AC\u003c\/span\u003e\u003c\/b\u003e (\u003cspan class=\"math-inline\"\u003e50\/60 Hz\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRated Conditional Short-Circuit Current \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e10 kA\u003c\/span\u003e (when paired with upstream \u003cspan class=\"math-inline\"\u003eiC60N\u003c\/span\u003e\/gG fuse)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRated Breaking \u0026amp; Making Capacity \u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e1500 A\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModule Width\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e2 pitch of 18 mm\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e36 mm\u003c\/span\u003e total width)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eStandards \u0026amp; Certifications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN\/IEC 61008-1, CE, VDE, RoHS Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45850816381011,"sku":"A9R71263","price":75.76,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1166\/3720\/files\/images-2026-08-13T115340.721.jpg?v=1793612921","url":"https:\/\/www.obmgonline.com\/products\/acti-9-iid-rccb-2p-63a-30ma-type-ac","provider":"OBMG Online","version":"1.0","type":"link"}